Migrate pandapipes nets loaded from older saves to the current schema.
=====================================================================
Projects saved on pandapipes 0.13 pickle a pipe table that uses the old ``KMR …``
std-types and the removed ``diameter_m`` column. Loaded into 0.14 those nets crash
in ``pipeflow`` (``'DataFrame' object has no attribute 'inner_diameter_mm'``) and the
GUI still shows the obsolete KMR names. ``migrate_loaded_net`` upgrades such a net in
place so old projects open and recalculate.
:author: Dipl.-Ing. (FH) Jonas Pfeiffer
"""
import logging
import pandapipes as pp
from districtheatingsim.net_simulation_pandapipes.pipe_std_types import (
nearest_isoplus_for_kmr,
resolve_pipe_u_w_per_m2k,
)
logger = logging.getLogger(__name__)
[docs]
def migrate_loaded_net(net):
"""
Migrate a freshly loaded pandapipes net to the current (0.14) schema, in place.
- Re-anchor legacy ``KMR …`` pipe std-types to their ISOPLUS successors, taking
the diameter and heat-loss from the current catalog (the user's KMR pipes are
anchored as ISOPLUS in pandapipes 0.14).
- Ensure the pipe table has the 0.14 ``inner_diameter_mm`` column, deriving it
from the legacy ``diameter_m`` [m] for any pipe not covered by the remap.
:param net: The loaded pandapipes network.
:return: The same network, migrated.
"""
if not hasattr(net, "pipe") or len(net.pipe) == 0:
return net
# Use the CURRENT pandapipes pipe catalog (from a fresh net), NOT the one embedded
# in the loaded net — an old pickle ships its own std-types library that still holds
# the obsolete KMR types (so a lookup against the loaded net would never find ISOPLUS).
fresh = pp.create_empty_network(fluid="water")
catalog = pp.std_types.available_std_types(fresh, "pipe")
# Replace the net's embedded pipe std-types with the current catalog so the GUI
# offers ISOPLUS types and std_type lookups resolve to them.
if hasattr(net, "std_types") and "pipe" in getattr(net, "std_types", {}):
net.std_types["pipe"] = dict(fresh.std_types["pipe"])
# Derive the new per-pipe diameter column from the old one where it is missing.
if "inner_diameter_mm" not in net.pipe.columns and "diameter_m" in net.pipe.columns:
net.pipe["inner_diameter_mm"] = net.pipe["diameter_m"] * 1000.0
remapped = 0
if "std_type" in net.pipe.columns:
for idx in net.pipe.index:
isoplus = nearest_isoplus_for_kmr(net.pipe.at[idx, "std_type"], catalog)
if isoplus is None:
continue
props = catalog.loc[isoplus]
net.pipe.at[idx, "std_type"] = isoplus
net.pipe.at[idx, "inner_diameter_mm"] = props["inner_diameter_mm"]
if "outer_diameter_mm" in net.pipe.columns:
net.pipe.at[idx, "outer_diameter_mm"] = props["outer_diameter_mm"]
net.pipe.at[idx, "u_w_per_m2k"] = resolve_pipe_u_w_per_m2k(props)
remapped += 1
if remapped:
logger.info("Migrated %d KMR pipe(s) to ISOPLUS std-types", remapped)
return net